Anti Termite

Pest Clear world offers customer anti-termite services that are designed to take care of subterranean termites. Termites are white tinny insect that tends to live in underground colonies and enter human dwellings through concrete gaps/voids. Commonly known as white ants, these termites destroy documents, valuable property, furniture and furnishings.

Chemical Used in treatment:

IMIDACLOPRID 30.5% SC: 5ml Per Liter of water

Method of Treatment

In pre construction treatment we apply Chemical solution at the suggested rate in all the following three stages:

STAGE 1: Treat bottom surface and sides (up to 30cm height) of the excavations made for column pits, wall trenches and basements @5L per sq.m. of surface area.

STAGE 2: Treat and backfill soil on both sides of all built up walls (approximate width 30cm and depth 45cm) @7.5L per sq.m. of vertical surface of substructure.

STAGE 3: Treat the entire leveled surface (before laying the floor) ©5L per sq.m. If necessary make 5 cm deep rod holes, 30 cm apart to facilities absorption.

External Treatment: Masonry Foundation

  • Dig shovel width trenches along the external wall of the building exposing the foundation wall surface up to a depth of 50 cm. Make 30 - 50 cm deep rod holes 15cm apart all along this trench. Pour this premium Imidacloprid 30.5% SC @1.75 Ltr per running meter.
  • Directly spray towards the wall surface.

Masonry Apron

If there is a concrete or masonry apron around the building, drill 12mm holes as close as possible to the plinth wall, 30cm apart. Pump Imidacloprid 30.5% SC to soak the soil @ 2.25L per linear meter.

RCC Framed Structure

In case of RCC framed structures with columns and plinth beams and RCC basements, the treatment can start at a depth of 50 cm below ground level. Excavate shovel width trenches exposing the sides of the column and plinth beams up to 30cm (or bottom of the plinth beam) and treat the backfill earth with Imidacloprid 30.5% SC while returning it to the trench @7.5L per sq.m of the vertical surface of the structure.

Soil Surrounding Pipes, Wastes And Conduits

Wherever pipes, wastes and conduits enter the soil, we will dig the area for a 15 cm wide and 7.5 cm in depth and thoroughly drench with Imidacloprid 30.5% SC solution.

Soil Under Floors

Drill 12 mm holes at the junction of floor and walls along the cracks on the floor and along constructional joints at 30cm intervals to reach the soil below. Squirt the Chemical solution 1L per hole or till refusal and seal the holes properly.

Protection of Wood Work

Drill 6mm holes at downward angle of 45 degree in the wood work at its junction with masonry walls or floors. Squirt the Imidacloprid 30.5% SC solution @0.5 L per hole or till refusal and seal the holes properly